What are the factors that need to be considered in the purchase of cooling fans? With regard to this issue, let's make a detailed explanation of the San Ju motors in Taiwan, a manufacturer of cooling fans, and learn it together.

Many businesses ignore a problem when purchasing cooling fans. All motors and electronic products that need to use a cooling fan must choose a cooling fan with enough air volume for the heat dissipation of the system, and the air volume depends on the power consumption of the system and whether enough heat can be taken away. In daily life, the service life of motors and electronic products that need to use cooling fans often decreases due to the shortage of cooling systems.Therefore, as an enterprise, it should also be understood that due to the shortage of cooling systems for cooling fans, the sales price and sales volume of motors and electronic products are often not as good as expected.Therefore, to select the correct cooling fan ventilation components, the following objectives must be considered as the standard:

First, the strongest air flow rate;

Second, the most suitable size;

Third, the quietest noise

; Fourth, the minimum power consumption;

Fifth, maximum reliability and maximum service life.

Sixth, the reasonable total cost

Having understood the above objectives and standards, we can help you achieve the above objectives through the following four steps to correctly select the cooling fan

Step 1:Total Cooling Requirements

First, three key factors must be understood in order to obtain total cooling requirements:

1.Heat that must be converted by the cooling fan ( i.e.temperature difference DT )

2.Watts ( W ) of the heat dissipation fan to offset the converted heat

3.The air volume ( CFM ) required by the cooling fan to remove heat

The total cooling requirement is extremely important for the effective operation of the system. Effective system operation must provide ideal operating conditions so that all components in the system can perform their maximum functions and the longest service life.

The following methods can be used to select a common cooling fan motor:

1.Calculate the heat generated inside the equipment.

2.Determine the allowable temperature rise range inside the equipment.

3.The equation calculates the required air volume.

4.Estimate the system impedance for the equipment.

5.Select the required cooling fan according to the characteristic curve or specification of the catalog.

If the amount of heat dissipation inside the system equipment and the allowed total temperature rise are known, the required air volume for cooling the equipment can be obtained.

Step 2:All system impedance/system characteristic curves

When the air flows, the air flow will meet the obstruction of the internal parts of the system in its flow path, and its resistance will restrict the free flow of air. The change in pressure is the measured static pressure.

In order to confirm the cooling wattage between each slot, the design or manufacturer of the cooling fan system must not only have the effective cooling fan characteristic curve of the cooling fan to determine its maximum air volume, but also know the wind resistance curve of the system. Parts inside the system can cause loss of wind pressure. This loss varies with the air volume, the so-called system impedance.

Step 3:System Operation Work Point

The intersection of the system characteristic curve and the cooling fan characteristic curve is called the system operating point, which is the optimal operating point of the cooling fan.

Step 4:Noise Value

The noise of the cooling fan is measured in a reverberation-free room with a background noise of less than 15 dBA. The cooling fan to be tested runs in free air and disposes of a noise meter one meter from the air inlet.

The following seven guidelines provide the best way to use a cooling fan to reduce noise to a minimum:

1.System impedance

The range between the air inlet and the air outlet of a casing accounts for 60 % to 80 % of the total system impedance, and the larger the airflow, the higher the noise. The higher the system impedance, the greater the airflow required for cooling, so in order to minimize noise, the system impedance must be minimized.

2.Air turbulence

Disturbances caused by obstacles encountered along the air flow path can generate noise. Therefore, any obstruction, especially in the critical air inlet and outlet areas, must be avoided in order to reduce noise.

3.Speed and size of cooling fan

Since the high-speed cooling fan generates more noise than the low-speed cooling fan, the low-speed cooling fan should be tried and selected as much as possible. However, a cooling fan with larger size and lower rotating speed is usually quieter than a cooling fan with smaller size and higher rotating speed when delivering the same air volume.

4.Temperature rise

In a system, the air volume required for cooling is inversely proportional to the allowable temperature rise. If the temperature rise is allowed to increase slightly, the required air volume can be greatly reduced. Therefore, if the restrictions imposed on the allowable temperature rise are slightly relaxed, the required air volume and noise can be reduced.

5.Vibration

In some cases, when the weight of the whole system is very light or the system must operate according to certain regulations, it is especially recommended to use soft insulation equipment to avoid the transmission of vibration of the cooling fan.

6.Voltage variation

Voltage variation will affect the noise level. The higher the voltage applied to the fan, the greater the vibration and the greater the noise due to the increase in the rotational speed.

7.Design considerations:

The design of every part that makes up the cooling fan will affect the noise level.

Taiwan's Three Giant Warm Tips:Choosing the right cooling fan for your electronic products can effectively reduce product energy consumption and prolong equipment service life


?
Service
top
主站蜘蛛池模板: 成人一区二区三区在线 | 热久精品 | 久久久av免费 | 超碰在线观看97 | 在线va网站 | www.久久成人 | 国产精品白浆视频 | 在线观看亚洲电影 | 久久免费毛片视频 | 99视频在线精品免费观看2 | 久久只精品99品免费久23小说 | 国产精品成人一区二区 | 亚洲最大免费成人网 | 欧美一区二视频在线免费观看 | 国产精品美女久久久久久久久 | 久草网在线观看 | 亚洲一区不卡视频 | 国产成人61精品免费看片 | 99久热在线精品视频观看 | 国产成人免费网站 | 麻豆视频在线免费看 | 亚洲国内在线 | 久久再线视频 | 国产精品免费麻豆入口 | 日韩黄色一级电影 | 亚洲一区日韩在线 | 日日爱网址| 欧美日韩中文字幕综合视频 | 成人午夜免费福利 | 国产精品黄色在线观看 | 亚洲在线视频播放 | 日韩精品一区不卡 | 免费视频网 | 亚洲欧洲成人精品av97 | 精品欧美一区二区精品久久 | a精品视频| 欧美日韩国产mv | 精品综合久久久 | 色综合天天色综合 | 国产伦精品一区二区三区四区视频 | 欧美一级电影免费观看 | 日韩理论在线视频 | 丁香六月色 | 91免费观看网站 | 毛片随便看 | 美女久久精品 | 在线综合色 | 又黄又爽又湿又无遮挡的在线视频 | 成人一级片视频 | 日本黄色a级大片 | 一区二区三区视频在线 | 免费日韩在线 | www天天干com| 久久九九精品久久 | 国产一区二区视频在线播放 | 婷婷亚洲综合五月天小说 | 一区二区三区不卡在线 | 高清有码中文字幕 | 国产一级一片免费播放放 | 最新国产精品久久精品 | 欧美日韩网址 | 欧美在线日韩在线 | 亚洲成人av在线 | 亚洲精品综合在线 | 91社区国产高清 | 久久草在线免费 | 91精品导航 | 91精品老司机久久一区啪 | 中文字幕视频一区二区 | 99久久精品国 | 欧美一区二区免费在线观看 | 五月婷婷丁香网 | 欧美xxxxx在线视频 | 欧美日韩一区二区三区不卡 | 久久观看最新视频 | 欧美一区日韩精品 | 欧美另类色图 | 久久精品久久久久电影 | 国产一区在线免费 | 在线免费观看视频你懂的 | 国产精品久久久久影院 | 久久电影日韩 | 91中文视频| 激情图片久久 | 亚洲国产美女精品久久久久∴ | a在线播放 | 在线观看国产v片 | 亚洲精品久久久久久中文传媒 | 久久免费a| 九九交易行官网 | 午夜91在线| 久久久精品一区二区 | 午夜的福利 | 亚洲综合在线观看视频 | 午夜免费福利片 | 激情综合色播五月 | 亚洲精品综合一二三区在线观看 | 九九视频在线观看视频6 | 国内精品久久久久影院一蜜桃 |